S Satya Prakash Khuntia (4baseCare Precision Health Pvt Ltd., Bengaluru, India) H Hitesh Goswami (4baseCare Precision Health Pvt Ltd., Bengaluru, India) K Kshitij Rishi (4baseCare Precision Health Pvt Ltd., Bengaluru, India) S Shefali Karve (4baseCare Precision Health Pvt Ltd., Bengaluru, India) P Puneet Pantane (4baseCare Precision Health Pvt. Ltd, Bengaluru, India) P Prabakar Sampath (4baseCare Precision Health Pvt. Ltd, Bengaluru, India) A Anjali Kulkarni (4baseCare Precision Health Pvt Ltd., Bengaluru, India) P Praveen Kumar Jha (4baseCare Precision Health Pvt. Ltd, Bengaluru, India)

Abstract

23 Background: Accurate tumor cell abundance (TCA) estimation is critical for ensuring sample adequacy prior to next-generation sequencing (NGS) in precision oncology workflows. Current standard practice requires manual pathologist review of hematoxylin and eosin stained whole slide images (WSI), creating throughput bottlenecks and inter-observer variability. We developed and evaluated a series of lightweight CNN models for cancer-agnostic TCA estimation to automate NGS quality control. Methods: Over 1,000 WSIs spanning multiple tumor types were processed using Otsu-based tissue segmentation. Tile-level pseudo-labels were generated using an ensemble of CellViT models, with slide-level TCA computed as the minimum of area-based and cell-based estimates across the ensemble. All slide-level TCA labels were independently validated by board-certified pathologists, with discordant cases reviewed and reconciled prior to model training. Four CNN architectures were evaluated: MobileNetV3, GoogLeNet, ResNet, and DenseNet. Models were trained via knowledge distillation from the CellViT ensemble and validated against pathologist-confirmed TCA estimates. Performance was assessed using MAE, AUC, and clinical concordance at a 20% TCA threshold for NGS adequacy determination. Results: All four models achieved AUC greater than 0.91 for NGS adequacy classification at the 20% TCA threshold, with MAE under 7% against pathologist-confirmed reference standards across all tumor types evaluated. Higher capacity architectures demonstrated marginal accuracy gains while MobileNetV3 achieved comparable performance at significantly faster inference speed, processing a complete WSI in under 5 seconds. Conclusions: Lightweight CNN models trained via knowledge distillation from a CellViT ensemble and pathologist-confirmed labels can achieve clinically acceptable cancer-agnostic TCA estimation suitable for automated NGS QC workflows. Compared to large Vision Transformer models requiring substantial computational resources, the distilled CNN models offer dramatically reduced inference cost while preserving clinical-grade accuracy. These models have potential to substantially reduce pathologist workload in molecular pathology laboratories while maintaining accuracy required for NGS adequacy determination, with direct applicability to precision oncology treatment selection pipelines and broad accessibility across resource-varied clinical settings.

Article Details

Volume / Issue Vol. 44, Issue 19_suppl
Published July 01, 2026
Pages 23-23
ISSN 0732-183X
Publisher Lippincott Williams & Wilkins

Journal Info

Journal of Clinical Oncology

Lippincott Williams & Wilkins

ISSN: 0732-183X Health Sciences

Authors (8)

S

Satya Prakash Khuntia

4baseCare Precision Health Pvt Ltd., Bengaluru, India

H

Hitesh Goswami

4baseCare Precision Health Pvt Ltd., Bengaluru, India

K

Kshitij Rishi

4baseCare Precision Health Pvt Ltd., Bengaluru, India

S

Shefali Karve

4baseCare Precision Health Pvt Ltd., Bengaluru, India

P

Puneet Pantane

4baseCare Precision Health Pvt. Ltd, Bengaluru, India

P

Prabakar Sampath

4baseCare Precision Health Pvt. Ltd, Bengaluru, India

A

Anjali Kulkarni

4baseCare Precision Health Pvt Ltd., Bengaluru, India

P

Praveen Kumar Jha

4baseCare Precision Health Pvt. Ltd, Bengaluru, India